Air Oxygen Blenders

Leading Manufacturers, Exporters and Wholesaler of SHI-17 Air Oxygen Blender, SHI-23 Air Oxygen Blender, SHI-24 Air Oxygen Blender and SHI-26 Air Oxygen Blender from Greater Noida.

Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Type Blender
Voltage 220V
Certification ISI Certified, CE Certified
Automatic Grade Manual
Condition New
Driven Type Electric
Brand Name S S Technomed (p) Limited

Click to view more

Product Description

 

Newborn / premature baby special equipment:

  • It is a sort of equipment used by medical staff who make rescue measures by using different concentration of oxygen, suitable for neonate especially premature infant to treat the oxygen damage and other complications, such as retinopathy of premature children(ROP), and chronic lung disease(CLD) due to absorbing high flow and concentrations oxygen for a long time. The product complies with requirements of the “Guide”. It must use the device that mixed with air and oxygen, strictly gasp the indications and ways of using oxygen, monitor and adjust the concentration in time according to the condition of patients to avoid excessive fluctuation


Product Performance Characteristics:

  • It is used on the course that strictly requires for oxygen concentration, such as hood, nasal catheter, incubator, infant resuscitator, heart lung machine.
  • The different concentrations of medical oxygen will be configured by adjusting the proportion of oxygen and air
  • The surface is processing with anodic oxidation.
  • Equipped with a regulating valve that can adjust the proportion of oxygen concentration, and a device that make the pressure stable, in order to output the constant pressure.
  • Adjust the oxygen concentrations and flow respectively.
  • The structure with double output port, it can supply gas for one or more patients at the same time.
  • Inside an alarm system of differential pressure. When alarming, the safety valve starts automatically and produces the mixture gas continuously to ensure the safety of patients.


Performance Parameters

  • Model: (SHI-17)
  • Oxygen concentration adjustment: 21% to 100%
  • Flow regulation: 0 ~ 18LPM (optional dual flow meter dual output).
Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Type Blender
Voltage 220V
Certification ISI Certified, CE Certified
Condition New
Driven Type Electric
Brand Name S S Technomed (p) Limited
Newborn / Premature Baby Special Equipment

This equipment is designed for medical staff to perform rescue measures using various concentrations of oxygen, specifically for neonates, especially premature infants. It helps in treating oxygen damage and complications such as:

  • Retinopathy of Prematurity (ROP)

  • Chronic Lung Disease (CLD)

These conditions may occur due to prolonged exposure to high-flow, high-concentration oxygen. The product complies with the relevant medical guidelines. It must be used with a device that mixes air and oxygen, while:

  • Strictly following indications and methods of oxygen use

  • Monitoring and adjusting oxygen concentration in real-time

  • Avoiding excessive fluctuations in oxygen levels

Product Performance Characteristics
  • Suitable for procedures requiring precise oxygen concentration control, such as:

    • Hood

    • Nasal catheter

    • Incubator

    • Infant resuscitator

    • Heart-lung machine

  • Configures different concentrations of medical oxygen by adjusting the proportion of oxygen and air

  • Surface treated with anodic oxidation for durability

  • Regulating valve allows for adjustment of oxygen concentration

  • Equipped with a pressure stabilizing device to ensure constant pressure output

  • Separate control of oxygen concentration and flow

  • Double output port structure, capable of supplying gas to one or more patients simultaneously

  • Built-in differential pressure alarm system

    • When triggered, the safety valve activates automatically

    • Continues to produce mixed gas to ensure patient safety

Performance Parameters

 

  • Model: SHI-23

  • Optional dual output configuration

  • Oxygen concentration adjustment: 21% to 100%

  • Optional attachments: Flow meter / Inhaler

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Brand Name S S Technomed (p) Limited
Driven Type Electric
Condition New
Voltage 220V
Type Blender
Country of Origin India
Delivery Time Depends on the order
Packaging Details Box

Click to view more

Newborn / Premature Baby Special Equipment

This is a type of medical equipment used by healthcare professionals to perform rescue interventions using different concentrations of oxygen. It is particularly suitable for neonates, especially premature infants, in the treatment of oxygen-induced damage and complications such as:

  • Retinopathy of Prematurity (ROP)

  • Chronic Lung Disease (CLD)

These conditions can occur due to prolonged exposure to high-flow and high-concentration oxygen. The product complies with the requirements of the medical “Guide”.

It is essential to:

  • Use a device that mixes air and oxygen

  • Strictly follow the indications and methods of oxygen use

  • Monitor and adjust the oxygen concentration in real-time according to the patient’s condition

  • Avoid excessive fluctuations in oxygen levels

Product Performance Characteristics
  • Used in applications requiring precise oxygen concentration control, such as:

    • Hood

    • Nasal catheter

    • Incubator

    • Infant resuscitator

    • Heart-lung machine

  • Configures different oxygen concentrations by adjusting the oxygen-to-air ratio

  • Surface treated with anodic oxidation for enhanced durability

  • Equipped with:

    • A regulating valve to adjust oxygen concentration

    • A pressure stabilizing device to maintain constant pressure output

  • Independent control of both oxygen concentration and flow rate

  • Double output port structure, allowing gas supply to one or multiple patients simultaneously

  • Integrated differential pressure alarm system

    • When triggered, the safety valve activates automatically

    • Continues producing mixed gas to ensure patient safety

Performance Parameters
  • Model: SHI-26

  • Oxygen concentration adjustment: 21% to 100%

  • Flow rate options:

    • 0.1 LPM ~ 1.0 LPM (dual output)

    • 0.1 LPM ~ 10 LPM

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Type Blender
Certification CE Certified
Condition New
Driven Type Electric
Brand Name S S Technomed (p) Limited
ISI Certified Yes
Delivery Time Depends on the order
Packaging Details Box

Click to view more

Newborn / Premature Baby Special Equipment

This equipment is designed for medical personnel to carry out rescue measures using various concentrations of oxygen. It is particularly suitable for neonates, especially premature infants, to treat oxygen-related complications such as:

  • Retinopathy of Prematurity (ROP)

  • Chronic Lung Disease (CLD)

These complications often result from prolonged exposure to high-flow and high-concentration oxygen. The product complies with the requirements of the “Guide”. It must be used in conjunction with a device that mixes air and oxygen, following the correct usage guidelines, and continuously:

  • Monitoring and adjusting the oxygen concentration based on the patient’s condition

  • Avoiding excessive fluctuation in oxygen delivery

Product Performance Characteristics
  • Used in procedures that require precise oxygen concentration, such as:

    • Hood

    • Nasal catheter

    • Incubator

    • Infant resuscitator

    • Heart-lung machine

  • Adjustable oxygen concentration by varying the proportion of oxygen and air

  • Anodic oxidation-treated surface for enhanced durability

  • Equipped with:

    • A regulating valve to fine-tune oxygen concentration

    • A pressure stabilizer to maintain constant output pressure

  • Independent control of both oxygen concentration and flow rate

  • Double output port structure, capable of supplying gas to one or more patients simultaneously

  • Built-in differential pressure alarm system

    • If triggered, the safety valve automatically activates

    • Continuously produces mixed gas to ensure patient safety

Performance Parameters
  • Model: SHI-26

  • Oxygen concentration adjustment range: 21% to 100%

  • Flow rate:

    • 0.1 LPM to 1.0 LPM (dual output)

    • 0.1 LPM to 10 LPM

Read More...


Request to Call


Enquiry Now



Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.